Skip to main content
  • UA
  • EN
  • RU
  • Thermal analyzer, TMA-60, Shimadzu

    Thermal analyzer, TMA-60, Shimadzu

    Available on back-order

    Article: tma-60

    Full warranty of 12 months

    Repair, replacement of parts, 24/7 technical support

    Quality control

    Verification in real production conditions

    Installation and adjustment

    Setting up and checking the functionality of the equipment

    Staff Training

    Training operators to work with the equipment and providing practical demonstrations of its functionality.

    COST CALCULATION REQUEST
    Equipment description

    Thermal analyzer, TMA-60, Shimadzu

    Thermomechanical analyzers

    Analyzers of this series are used in the study of a wide range of materials with an assessment of their mechanical characteristics, using a set of standard measurement modes (tension, expansion, penetration). At the same time, the TMA-60 model uses the method of measuring linear expansion (one sensor is used), and the TMA-60N uses the method of measuring differential expansion (two sensors are used).

    Features

    • The high accuracy of the analysis and the wide dynamic is greatly increased due to the range of the high-precision digital displacement sensor. At the same time, a wide measurement range of ±5 mm is possible (twice as much as in the previous model), which ensures accurate determination of both small and large deformations of the sample.
    • A diverse program makes it possible to subject images (films, fibers, etc.) to various static and dynamic influences with a constant rate of loading or elongation, to work in a cyclic mode.
    • The use of a bayonet connection in the design of the sample holder and a built-in temperature sensor ensures simple operation (repair, if necessary) and increases the speed of changing measurement modes (stretching, expansion, penetration).
    • A built-in safety mechanism prevents the sample from sticking to the sensor. If the displacement is above the specified range, for example due to melting of the sample, the measurement is stopped immediately and the load is removed from the sample.
    • Accurate automatic determination of the length of the sample due to direct measurement by a high-precision digital displacement sensor (measurement is more accurate, compared to other methods, in which the calculation is based on stopping the movement of the motor).
    • The devices are equipped with a cooling fan that automatically cools the furnace after the measurements are completed.
    Characteristics

    Thermal analyzer, TMA-60, Shimadzu

    FIND OUT THE COST OF EQUIPMENT BY PHONE

    Leave your contact details, our manager will contact you and calculate the cost of the necessary equipment

    footer form eng

    If you want to contact us in another way, please email us at info@holeks.tech

    We provide full support at every stage of project implementation - we offer minimum delivery terms and various terms of payment, debugging and warranty service.

    We are on social networks:


    Copyright © 2023 Holeks Tech. All rights reserved